Project Details
Description
Over the last decades, there has been a rapid increase of using ultrasound arrays to detect and characterize defects. Particularly, post-processing imaging algorithms such as Total Focusing Method (TFM) can be used on a full set of captured matrix data (FMC) to perform high-resolution imaging. However, due to the diffraction of waves, the imaging resolution of ultrasound array is limited to around a wavelength of the ultrasound in use, and this leaves high uncertainty to small defect characterization from its ultrasound image. The scattering behaviour from small defects can be extracted (scattering matrix) and used to characterise it. However, the accuracy of characterising procedure is affected by surrounding noise and defect surface condition such as roughness and asperities. This limits the real application of defect characterization using ultrasonic arrays in practice (within 0.1 wavelength accuracy). This project will look to develop a method to characterise defects more accurately by suppressing the effect from surrounding noise and defect surface condition.
| Status | Finished |
|---|---|
| Effective start/end date | 27/09/22 → 27/09/26 |
Fingerprint
Explore the research topics touched on by this project. These labels are generated based on the underlying awards/grants. Together they form a unique fingerprint.