A quantitative evaluation of aerosol generation during tracheal intubation and extubation

Jules Brown, Flo K A Gregson, Andrew J Shrimpton, Tim M Cook, Bryan R Bzdek, Jonathan P Reid, Anthony E Pickering*

*Corresponding author for this work

Research output: Contribution to journalArticle (Academic Journal)peer-review

144 Citations (Scopus)
829 Downloads (Pure)

Abstract

The potential aerosolised transmission of severe acute respiratory syndrome coronavirus-2 is of global concern. Airborne precaution personal protective equipment and preventative measures are universally mandated for medical procedures deemed to be aerosol generating. The implementation of these measures is having a huge impact on healthcare provision. There is currently a lack of quantitative evidence on the number and size of airborne particles produced during aerosol-generating procedures to inform risk assessments. To address this evidence gap, we conducted real-time, high-resolution environmental monitoring in ultraclean ventilation operating theatres during tracheal intubation and extubation sequences. Continuous sampling with an optical particle sizer allowed characterisation of aerosol generation within the zone between the patient and anaesthetist. Aerosol monitoring showed a very low background particle count (0.4 particles.l−1) allowing resolution of transient increases in airborne particles associated with airway management. As a positive reference control, we quantitated the aerosol produced in the same setting by a volitional cough (average concentration, 732 (418) particles.l−1, n = 38). Tracheal intubation including facemask ventilation produced very low quantities of aerosolised particles (average concentration, 1.4 (1.4) particles.l−1, n = 14, p < 0.0001 vs. cough). Tracheal extubation, particularly when the patient coughed, produced a detectable aerosol (21 (18) l−1, n = 10) which was 15-fold greater than intubation (p = 0.0004) but 35-fold less than a volitional cough (p < 0.0001). The study does not support the designation of elective tracheal intubation as an aerosol-generating procedure. Extubation generates more detectable aerosol than intubation but falls below the current criterion for designation as a high-risk aerosol-generating procedure. These novel findings from real-time aerosol detection in a routine healthcare setting provide a quantitative methodology for risk assessment that can be extended to other airway management techniques and clinical settings. They also indicate the need for reappraisal of what constitutes an aerosol-generating procedure and the associated precautions for routine anaesthetic airway management.
Original languageEnglish
Pages (from-to)174-181
Number of pages8
JournalAnaesthesia
Volume76
Issue number2
Early online date6 Oct 2020
DOIs
Publication statusPublished - 9 Jan 2021

Research Groups and Themes

  • Anaesthesia Pain and Critical Care
  • Covid19
  • UNCOVER

Keywords

  • Intubation
  • Extubation
  • SARS-COV-2
  • COVID-19
  • Aerosol Generating Procedure