Skip to content

Biomechanical evaluation of simulated feline patella fracture repairs

Research output: Contribution to journalArticle

Original languageEnglish
Pages (from-to)125-130
Number of pages6
JournalVeterinary and Comparative Orthopaedics and Traumatology
Volume2017
Issue number2
Early online date17 Jan 2017
DOIs
DateAccepted/In press - 7 Nov 2016
DateE-pub ahead of print - 17 Jan 2017
DatePublished (current) - Feb 2017

Abstract

Objective: To investigate four techniques for stabilisation of feline patellar fracture.

Methods: Feline cadaveric stifles with simulated patellar fracture were stabilised with one of four techniques: Group A-circumferential wire, group B-figure eight wire, group C-combined figure eight and circumferential wire, group D-pin and tension band wire. All repairs were subjected to a period of cyclic loading prior to load to failure testing. Experiments were recorded by video capture to determine load at failure and failure mode. Failure was defined as an opening of the fracture gap of 3mm.

Results: Mean fracture gap opening (±SD) during peak loading after 1000 cycles was: group A-1.66mm (± 0.69), group B-1.01mm (± 0.45), group C-0.81mm (± 0.58), group D-0.65mm (± 0.54). Groups C and D had statistically lower mean fracture gap opening after 1000 cycles when compared to group A (p<0.05).
Mean loads (+/-SD) at failure were: group A–171.4 (+/-62.2)N, group B–208.7 (+/-20.7)N, group C–288.2 (+/-62.5)N and group D–219.5 (+/-48.0)N. Group C had statistically higher mean load to failure than all other groups (p<0.05). There was no difference between other groups. In groups A, B and C the principle mode of failure was wire elongation and tearing of sutures through the retinaculae and periarticular soft tissues. In group D the principle mode of failure was the pin pulling through the bone of the distal fragment.

Conclusions: Combined figure 8 and circumferential wires may be useful for treatment of transverse feline patellar fracture repair.

    Research areas

  • Feline , Patellar fracture, biomechanical

Download statistics

No data available

Documents

Documents

  • Full-text PDF (accepted author manuscript)

    Rights statement: This is the author accepted manuscript (AAM). The final published version (version of record) is available online via Schattauer at https://vcot.schattauer.de/contents/archivestandard/issue/special/manuscript/27050.html. Please refer to any applicable terms of use of the publisher.

    Accepted author manuscript, 66.2 MB, PDF document

DOI

View research connections

Related faculties, schools or groups