Computational analysis of mechanical performance for 3D-printed biodegradable PLA cardiovascular stents

Research output: Contribution to journalArticle (Academic Journal)peer-review

Abstract

Cardiovascular stents are widely applied in the treatment of arterial stenosis, but conventional metallic stents present limitations such as permanent implantation, hypersensitivity reactions, and late restenosis. Biodegradable polymer stents offer a promising alternative, though their translation is restricted by structural design challenges and inadequate mechanical performance. In this study, eight representative stent architectures were computationally evaluated with respect to radial elastic recoil, foreshortening, dogboning, and radial support force. Stents were fabricated from polylactide (PLA) via fused deposition modelling (FDM), and the effects of nozzle temperature, layer height, and printing speed were systematically assessed on PLA dogbone specimens to determine optimised process parameters. Computational analysis revealed that only type B and type F stents met clinical deformation requirements, with radial elastic recoil <6 %, foreshortening <10 %, and dogboning <10 %, while other designs exhibited values exceeding these thresholds. Parallel compression tests further quantified radial support capacity at 50 % compression. Fabrication and dimensional evaluation showed that, although all stent designs could be produced using optimised FDM parameters, manufacturing-induced geometric deviations at thin struts and unit connection regions were unavoidable. As a result, the finite-element simulations should be regarded as providing idealised mechanical responses for comparative design evaluation rather than exact predictions of fabricated prototypes. Overall, these findings provide structural and process design guidelines for the development of mechanically reliable 3D-printed biodegradable PLA cardiovascular stents, while emphasising the importance of manufacturing fidelity when translating computationally optimised designs into physical devices.
Original languageEnglish
Article number107355
Number of pages14
JournalJournal of the Mechanical Behavior of Biomedical Materials
Volume176
Early online date29 Jan 2026
DOIs
Publication statusE-pub ahead of print - 29 Jan 2026

Bibliographical note

Publisher Copyright:
© 2026 The Authors

Fingerprint

Dive into the research topics of 'Computational analysis of mechanical performance for 3D-printed biodegradable PLA cardiovascular stents'. Together they form a unique fingerprint.

Cite this