The use of 2D ultrasonic arrays provides great flexibility, as one array probe allows a given defect to be illuminated from a wide range of angles. However there are a number of challenges in the application of 2D arrays to detection and characterization of 3D defects. In the current paper the problem of finding the optimal array configuration for defects detection in thin sections is investigated. The efficient FE scattering model is used to simulate an ultrasonic array response for different 3D defects. The data provided by this model is then used to analyze the influence of different parameters on the array performance (signal to noise ratio, sensitivity, resolution). Finally, experimental results are shown that illustrate the imaging performance of optimal 2D array configuration.

Original languageEnglish
Title of host publicationREVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 32A AND 32B
EditorsDO Thompson, DE Chimenti
Place of PublicationMELVILLE
PublisherAmerican Institute of Physics (AIP)
Pages841-848
Number of pages8
ISBN (Print)978-0-7354-1129-6
DOIs
Publication statusPublished - 2013
Event39th Annual Review of Progress in Quantitative Nondestructive Evaluation (QNDE 2012) - Denver, CO, United States
Duration: 15 Jul 2012 → 20 Jul 2012
Conference number: 39

Publication series

NameAIP Conference Proceedings
PublisherAMER INST PHYSICS
Volume1511
ISSN (Print)0094-243X

Conference

Conference39th Annual Review of Progress in Quantitative Nondestructive Evaluation (QNDE 2012)
Abbreviated titleQNDE 2012
Country/TerritoryUnited States
CityDenver, CO
Period15/07/12 → 20/07/12

Keywords

  • Scattering
  • Finite Elements
  • Ultrasonic Array
  • Imaging

Fingerprint

Dive into the research topics of 'DEFECTS DETECTION IN THIN COMPONENTS USING TWO-DIMENSIONAL ULTRASONIC ARRAYS'. Together they form a unique fingerprint.

Cite this