Abstract
Concrete is subjected to degradation when exposed to high temperatures, and the degree of degradation is based on the exposure temperature, duration and inherent material properties. High-temperature exposure affects the concrete structural integrity causing spalling, which occurs on the exposed surface due to pore pressure differences, thermal stresses and physio-chemical changes in the concrete. These changes are due to microstructural degradation of the matrix, resulting from changes in the chemical composition of the hydrated
concrete after exposure to high temperatures. Polypropylene fibres, due to their low melting point, contribute to spalling reduction in fibre-reinforced concrete by creating a vapour pressure dissipation network. The current experimental work focuses on the microstructural performance of Polypropylene Fibre-Reinforced Concrete (PPFRC) exposed to high temperatures of 300°C and 700°C. This work highlighted the changes in the microstructure of PPFRC before and after exposure, as observed through visual observations, Scanning Electron Microscopy (SEM), and X-Ray Diffraction (XRD) methods. The findings of visual observations were correlated with SEM images, which identified the presence of different chemical components in concrete. This study suggests that polypropylene fibre reduces spalling, as pictured in visual observation images. The microstructure of the hydrated and dehydrated matrix was visibly shown using SEM images. The XRD method was used to interpret the decomposition of hydration products, including C-S-H gel, C3S, C2S, and CH, when exposed to
700 °C. The conclusions were drawn based on this analysis, and further investigations were also recommended.
concrete after exposure to high temperatures. Polypropylene fibres, due to their low melting point, contribute to spalling reduction in fibre-reinforced concrete by creating a vapour pressure dissipation network. The current experimental work focuses on the microstructural performance of Polypropylene Fibre-Reinforced Concrete (PPFRC) exposed to high temperatures of 300°C and 700°C. This work highlighted the changes in the microstructure of PPFRC before and after exposure, as observed through visual observations, Scanning Electron Microscopy (SEM), and X-Ray Diffraction (XRD) methods. The findings of visual observations were correlated with SEM images, which identified the presence of different chemical components in concrete. This study suggests that polypropylene fibre reduces spalling, as pictured in visual observation images. The microstructure of the hydrated and dehydrated matrix was visibly shown using SEM images. The XRD method was used to interpret the decomposition of hydration products, including C-S-H gel, C3S, C2S, and CH, when exposed to
700 °C. The conclusions were drawn based on this analysis, and further investigations were also recommended.
| Original language | English |
|---|---|
| Title of host publication | 5th International Fire Safety Symposium (IFireSS 2025) |
| Editors | Ali Nadjai, Naveed Alam, Svetlana Tretsiakova-Mcnally |
| Place of Publication | Belfast |
| Pages | 557-566 |
| Number of pages | 10 |
| Volume | 1 |
| ISBN (Electronic) | 9781859232743 |
| DOIs | |
| Publication status | Published - 21 Jul 2025 |
| Event | International Fire Safety Symposium - Belfast, United Kingdom Duration: 25 Jun 2025 → 27 Jun 2025 https://www.ulster.ac.uk/conference/ifiress2025 |
Conference
| Conference | International Fire Safety Symposium |
|---|---|
| Abbreviated title | IFireSS 2025 |
| Country/Territory | United Kingdom |
| City | Belfast |
| Period | 25/06/25 → 27/06/25 |
| Internet address |
Keywords
- High-temperature
- Polypropylene Fibres
- Fibre-Reinforced Concrete
- Spalling
Fingerprint