TY - JOUR
T1 - High-Definition Intravascular Ultrasound Versus Optical Coherence Tomography
T2 - Lumen Size and Plaque Morphology
AU - Wu, Wei
AU - Zhao, Shijia
AU - Banga, Akshat
AU - Trivedi, Yash Vardhan
AU - Dasari, Vineeth S.
AU - Munjal, Parth
AU - Bhat, Rakshita Ramesh
AU - Tapia-Orihuela, Ruben K.A.
AU - Oguz, Usama M.
AU - Zafar, Hammad
AU - Darapaneni, Haritha
AU - Spilias, Nikolaos
AU - Wagner, Jessica
AU - Morin, Stephen
AU - DeVos, Amanda
AU - Iaizzo, Paul A.
AU - Maehara, Akiko
AU - Shlofmitz, Evan S.
AU - Ali, Ziad A.
AU - Brilakis, Emmanouil
AU - Dangas, George D.
AU - Johnson, Thomas
AU - Chatzizisis, Yiannis S.
N1 - Publisher Copyright:
© 2024 The Author(s)
PY - 2025/5/1
Y1 - 2025/5/1
N2 - Background: Complex percutaneous coronary interventions rely on advanced intravascular imaging techniques, such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT). This study aims to compare the accuracy of the latest high-definition intravascular ultrasound (HD IVUS) and OCT technologies in measuring coronary lumen dimensions and assessing plaque morphology. Methods: We compared HD IVUS and OCT in 8 silicone models using microcomputed tomography as the ground truth. We also compared HD IVUS vs OCT in 12 coronary arteries from 9 patients. Results: In the silicone models, the latest HD IVUS (AVVIGO+, Boston Scientific) system overestimated lumen dimensions compared to microcomputed tomography by +0.06 ± 0.05 mm for mean lumen diameter (MLD). OCT (Ultreon 2.0, Abbott) underestimated lumen dimensions by –0.17 ± 0.06 mm for MLD, with the underestimation being greater for lumen diameters ≥5.0 mm. In clinical cases, the latest HD IVUS (AVVIGO+) system yielded larger lumen dimensions compared to OCT (Ultreon 2.0) by +0.12 ± 0.11 mm for MLD, and the earlier HD IVUS (POLARIS, Boston Scientific) system also showed larger lumen dimensions compared to OCT (AptiVue, Abbott) by +0.26 ± 0.29 mm for MLD. Using OCT as the reference, HD IVUS detected fine wall structures with precision, such as a thin fibrous cap, dissection, and stent struts. Conclusions: The latest HD IVUS (Avvigo+) tends to overestimate lumen size, whereas OCT (Ultreon 2.0) underestimates it. Experimental data suggest HD IVUS provides more accurate lumen assessment, particularly in larger coronary arteries, although both technologies exhibit comparable overall accuracy in the clinical setting.
AB - Background: Complex percutaneous coronary interventions rely on advanced intravascular imaging techniques, such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT). This study aims to compare the accuracy of the latest high-definition intravascular ultrasound (HD IVUS) and OCT technologies in measuring coronary lumen dimensions and assessing plaque morphology. Methods: We compared HD IVUS and OCT in 8 silicone models using microcomputed tomography as the ground truth. We also compared HD IVUS vs OCT in 12 coronary arteries from 9 patients. Results: In the silicone models, the latest HD IVUS (AVVIGO+, Boston Scientific) system overestimated lumen dimensions compared to microcomputed tomography by +0.06 ± 0.05 mm for mean lumen diameter (MLD). OCT (Ultreon 2.0, Abbott) underestimated lumen dimensions by –0.17 ± 0.06 mm for MLD, with the underestimation being greater for lumen diameters ≥5.0 mm. In clinical cases, the latest HD IVUS (AVVIGO+) system yielded larger lumen dimensions compared to OCT (Ultreon 2.0) by +0.12 ± 0.11 mm for MLD, and the earlier HD IVUS (POLARIS, Boston Scientific) system also showed larger lumen dimensions compared to OCT (AptiVue, Abbott) by +0.26 ± 0.29 mm for MLD. Using OCT as the reference, HD IVUS detected fine wall structures with precision, such as a thin fibrous cap, dissection, and stent struts. Conclusions: The latest HD IVUS (Avvigo+) tends to overestimate lumen size, whereas OCT (Ultreon 2.0) underestimates it. Experimental data suggest HD IVUS provides more accurate lumen assessment, particularly in larger coronary arteries, although both technologies exhibit comparable overall accuracy in the clinical setting.
KW - coronary artery
KW - high-definition intravascular ultrasound
KW - microcomputed tomography
KW - optical coherence tomography
UR - https://www.scopus.com/pages/publications/105003978636
U2 - 10.1016/j.jscai.2024.102520
DO - 10.1016/j.jscai.2024.102520
M3 - Article (Academic Journal)
C2 - 40454284
AN - SCOPUS:105003978636
SN - 2772-9303
VL - 4
JO - Journal of the Society for Cardiovascular Angiography and Interventions
JF - Journal of the Society for Cardiovascular Angiography and Interventions
IS - 5
M1 - 102520
ER -