Abstract
In recent years, the tuned mass damper inerter (TMDI) has been demonstrated in several theoretical studies to be an effective vibration absorber for the seismic protection of non-isolated buildings. Its effectiveness relies on careful tuning of the TMDI stiffness and damping properties, while its performance improves with the increase of the inertance property which is readily scalable. Nevertheless, in all previous studies, the energy dissipative TMDI element has been modelled by a linear viscous damper. Still, commercial viscous dampers display a nonlinear velocity-dependent power law behavior. In this regard, this paper investigates, for the first time in literature, the potential of the TMDI fitted with nonlinear viscous damper (NVD) for seismic response protection of multi-storey buildings. This is supported by an efficient optimal nonlinear TMDI (NTMDI) tuning approach which accounts for any absorber connectivity to the building structure and employs statistical linearization to treat the nonlinear damp
| Original language | English |
|---|---|
| Pages (from-to) | 1509-1539 |
| Number of pages | 31 |
| Journal | Bulletin of Earthquake Engineering |
| Volume | 21 |
| Early online date | 10 Jan 2023 |
| DOIs | |
| Publication status | Published - 1 Feb 2023 |
Fingerprint
Dive into the research topics of 'Optimal design and assessment of tuned mass damper inerter with nonlinear viscous damper in seismically excited multi-storey buildings'. Together they form a unique fingerprint.Cite this