TY - JOUR
T1 - Systematic Review and Meta-Analysis of Studies Comparing the Rate of Post-operative Periprosthetic Fracture Following Hip Arthroplasty With a Polished Taper Slip versus Composite Beam Stem
AU - Mabrouk, Ahmed
AU - Feathers, Jacob R.
AU - Mahmood, Ansar
AU - West, Robert
AU - Pandit, Hemant
AU - Lamb, Jonathan N.
N1 - Publisher Copyright:
© 2023 Elsevier Inc.
PY - 2023/6/19
Y1 - 2023/6/19
N2 - Background: We compared the incidence of postoperative periprosthetic femoral fractures (POPFF) following hip arthroplasty with either a cemented polished taper slip (PTS) stem or a cemented composite beam (CB) stem in comparative studies. Methods: A systematic review of comparative studies, written in English and published in peer-reviewed journals since the year 2000, was conducted. Study quality was assessed using the Newcastle-Ottawa scale.The overall study qualities were good. There were 913,021 patients from 18 cohorts included in the meta-analysis. There were 294,540 patients who received a CB stem and 618,481 received a PTS stem. Cohorts were classified as high- or low-risk for POPFF based on patient risk factors. A metanalysis was performed using a random effects model, and the relative incidence with 95% confidence intervals (CIs) was reported. Results: The patients at low risk of POPFF had an incidence rate ratio of 3.14 (CI: 2.48, 3.98) for the PTS group versus the CB group. Whereas, the patients at high risk of POPFF had an incidence rate ratio of 9.87 (CI: 3.63, 26.80) for the PTS group versus the CB group. Conclusions: The risk of POPFF is lower when hip arthroplasty was performed using a CB stem versus a PTS stem. This protective effect was greatest in patients who had a higher risk of POPFF. Surgeons should consider the effect of cemented stem choice on the risk of subsequent periprosthetic femur fracture, particularly in frail or elderly patients who are at a higher risk of postoperative periprosthetic femoral fracture.
AB - Background: We compared the incidence of postoperative periprosthetic femoral fractures (POPFF) following hip arthroplasty with either a cemented polished taper slip (PTS) stem or a cemented composite beam (CB) stem in comparative studies. Methods: A systematic review of comparative studies, written in English and published in peer-reviewed journals since the year 2000, was conducted. Study quality was assessed using the Newcastle-Ottawa scale.The overall study qualities were good. There were 913,021 patients from 18 cohorts included in the meta-analysis. There were 294,540 patients who received a CB stem and 618,481 received a PTS stem. Cohorts were classified as high- or low-risk for POPFF based on patient risk factors. A metanalysis was performed using a random effects model, and the relative incidence with 95% confidence intervals (CIs) was reported. Results: The patients at low risk of POPFF had an incidence rate ratio of 3.14 (CI: 2.48, 3.98) for the PTS group versus the CB group. Whereas, the patients at high risk of POPFF had an incidence rate ratio of 9.87 (CI: 3.63, 26.80) for the PTS group versus the CB group. Conclusions: The risk of POPFF is lower when hip arthroplasty was performed using a CB stem versus a PTS stem. This protective effect was greatest in patients who had a higher risk of POPFF. Surgeons should consider the effect of cemented stem choice on the risk of subsequent periprosthetic femur fracture, particularly in frail or elderly patients who are at a higher risk of postoperative periprosthetic femoral fracture.
KW - composite beam
KW - hip hemiarthroplasty
KW - periprosthetic femur fracture
KW - polished taper slip
KW - total hip arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=85164591367&partnerID=8YFLogxK
U2 - 10.1016/j.arth.2023.06.014
DO - 10.1016/j.arth.2023.06.014
M3 - Article (Academic Journal)
C2 - 37343648
AN - SCOPUS:85164591367
SN - 0883-5403
VL - 39
SP - 269
EP - 275
JO - Journal of Arthroplasty
JF - Journal of Arthroplasty
IS - 1
ER -