TY - JOUR
T1 - The Transient Thermal Ageing of Eurofer 97 by Mitigated Plasma Disruptions
AU - Hargreaves, James P
AU - Tipping, Hannah E
AU - Moore, Stacy
AU - Kumar, David
AU - Harding, Lottie M
AU - Dominguez Andrade, Hugo
AU - Hanna, Peter D
AU - Dawson, Huw
AU - Martin, Tomas L
N1 - Publisher Copyright:
© 2024
PY - 2024/8/1
Y1 - 2024/8/1
N2 - Plasma disruptions in a commercial-scale tokamak will impose high magnitude, short-duration thermal loads on its plasma-facing first wall. Despite a plethora of mitigation measures, these severe, off-normal events are likely to briefly expose the structural materials of the first wall to significant temperature excursions. Eurofer 97, the reference structural material for the plasma-facing first wall of the EU DEMO tokamak, is a reduced activation 9Cr steel with a normalised and tempered ferritic/martensitic microstructure. Repeated exposure to the thermal effects of disruptions over the operating lifetime of a reactor may promote a cumulative evolution of Eurofer 97′s microstructure, affecting key material properties crucial to first wall performance. This novel transient thermal degradation mechanism has been explored via a laser-based transient heating experiment, supported by time-dependent finite element thermal analysis studies of DEMO’s water-cooled lithium–lead first wall during a mitigated plasma disruption. Transient-affected samples of Eurofer 97 were characterised via scanning and transmission electron microscopy techniques (SEM/TEM), including electron backscatter diffraction (EBSD), energy-dispersive X-ray spectroscopy (EDX), and selective area electron diffraction (SAED). Microhardness and magnetisation testing data are also presented. A single 700 °C thermal transient was found sufficient to coarsen and partially recrystallise Eurofer 97′s tempered martensite sub-grains at the tungsten-Eurofer 97 interface. Further transient exposure at 700 °C resulted in the significant growth of equiaxed grains, the nucleation of intergranular Cr-rich M7C3 and M23C6 carbides, and the coarsening of V-rich and intra-granular Ta-rich MX precipitates. The microstructural effects of 850 °C transients are also reported. Notably, after 1,000 transients at 850 °C the hardness of Eurofer 97 was found to have decreased by 32 %.
AB - Plasma disruptions in a commercial-scale tokamak will impose high magnitude, short-duration thermal loads on its plasma-facing first wall. Despite a plethora of mitigation measures, these severe, off-normal events are likely to briefly expose the structural materials of the first wall to significant temperature excursions. Eurofer 97, the reference structural material for the plasma-facing first wall of the EU DEMO tokamak, is a reduced activation 9Cr steel with a normalised and tempered ferritic/martensitic microstructure. Repeated exposure to the thermal effects of disruptions over the operating lifetime of a reactor may promote a cumulative evolution of Eurofer 97′s microstructure, affecting key material properties crucial to first wall performance. This novel transient thermal degradation mechanism has been explored via a laser-based transient heating experiment, supported by time-dependent finite element thermal analysis studies of DEMO’s water-cooled lithium–lead first wall during a mitigated plasma disruption. Transient-affected samples of Eurofer 97 were characterised via scanning and transmission electron microscopy techniques (SEM/TEM), including electron backscatter diffraction (EBSD), energy-dispersive X-ray spectroscopy (EDX), and selective area electron diffraction (SAED). Microhardness and magnetisation testing data are also presented. A single 700 °C thermal transient was found sufficient to coarsen and partially recrystallise Eurofer 97′s tempered martensite sub-grains at the tungsten-Eurofer 97 interface. Further transient exposure at 700 °C resulted in the significant growth of equiaxed grains, the nucleation of intergranular Cr-rich M7C3 and M23C6 carbides, and the coarsening of V-rich and intra-granular Ta-rich MX precipitates. The microstructural effects of 850 °C transients are also reported. Notably, after 1,000 transients at 850 °C the hardness of Eurofer 97 was found to have decreased by 32 %.
KW - fusion
KW - materials
U2 - 10.1016/j.matdes.2024.113207
DO - 10.1016/j.matdes.2024.113207
M3 - Article (Academic Journal)
SN - 0261-3069
VL - 244
JO - Materials and Design
JF - Materials and Design
IS - 113207
M1 - 113207
ER -