Abstract
In total hip arthroplasty 32 mm heads are often used as the greater diameter is thought to contribute to improved stability. However, greater head diameter can also lead to greater volumetric wear. We compared polyethylene wear between patients with 32 mm heads and those with smaller heads. All patients who had Harris Galante1 metal-backed, uncemented cups inserted between 1986 and 1996 at our institute were annually reviewed clinically and radiographically. Accelerated polyethylene wear was noted between the fifth and seventh postoperative year in 17 out of 165 total hip replacements with 32 mm heads, but only in 21 out of 961 total hip arthroplasties with smaller femoral heads. In all 17 THRs, accelerated wear was also associated with thin polyethylene (
Translated title of the contribution | Thirty-two millimetre heads and accelerated polyethylene wear in total hip arthroplasty |
---|---|
Original language | English |
Pages (from-to) | 207 - 209 |
Number of pages | 3 |
Journal | Hip International |
Volume | 16 (3) |
Publication status | Published - Jul 2006 |