Skip to main navigation Skip to search Skip to main content

A Measurement of Interference from D-mixing in D0→Kπππ events at LHCb during Run 2 of the LHC

Student thesis: Doctoral Thesis › Doctor of Philosophy (PhD)

Abstract

The time dependent ratio of wrong-sign D0 → K+π
−π
−π
+to right-sign D0 →
K−π
+π
+π
−decay rates is measured using 3.8fb−1
of proton-proton collision data
taken in 2017 and 2018 during Run 2 of the LHC at a centre of mass energy
of 13TeV. The D∗ → (D0 → Kπππ) π decay channels are used as the charge of
the bachelor pion tags the type of decay. The ratio of the wrong- to right-sign
amplitudes is measured to be
rD = (5.41 ± 0.07(stat.) ± 0.13(sys.)) × 102
which is consistent with the world average value of (5.50 ± 0.06) × 102 at the
1σ level. The interference between the wrong-sign and right-sign D0 → Kπππ
amplitudes is also measured, as this is a necessary input for future measurements of
the CKM angle γ using the related B → (D → Kπππ)K family of decay channels.
This interference has previously been measured in phase space bins at the CLEO-c
and BES-III experiments; using this same binning scheme, a method is presented
here where the constraints obtained at CLEO-c and BES-III are combined with
the result from D-mixing at LHCb. This constraint is improved using the result
from LHCb data. The dimensionless, complex charm interference parameter ZΩ is
used to parameterise the interference; in the four phase space bins the value of this
parameter are measured to be:

0.24+0.05
−0.04 ± 0.04
+ (−0.58 ± 0.10 ± 0.10) i
(0.67 ± 0.06 ± 0.03) +
−0.56+0.13
−0.14 ± 0.14
i
(0.75 ± 0.05 ± 0.016) +
−0.015+0.13
−0.12 ± 0.12
i
(0.03 ± 0.05 ± 0.02) +
0.63+0.11
−0.10 ± 0.12
i
where the first uncertainty presented is statistical and the second systematic.
The dominant source of systematic error is associated with correcting for
the detector efficiency; a novel method has been developed to evaluate this and
suggestions for reducing the associated uncertainty are presented. Using this
technique on the full LHCb dataset will enable an even more precise measurement
of the interference between the amplitudes. This can then be used for a precise
measurement of the CKM angle γ, an important parameter that is often used as
a benchmark for the Standard Model and that also enables searches for physics
beyond the Standard Model.
Date of Award5 Dec 2023
Original languageEnglish
Awarding Institution
  • University of Bristol
SupervisorJonas H Rademacker (Supervisor) & Konstantinos A. Petridis (Supervisor)

Cite this

'