Underactive bladder (UAB) condition is characterised by impaired detrusor muscle function and incomplete bladder emptying. Conventional clinical treatments, such as catheterisation, are invasive and leads to poor quality of life. Assistive actuation methods, such as shape memory alloy (SMA) spring actuators integrated with thin-film flexible sensors, offer a promising alternative. These actuators mechanically aid bladder voiding while estimating the bladder volume based on the sensors’ bending. However, directly monitoring the bladder fullness status by the bladder muscle biopotential signals is preferred. Therefore, this thesis explores the development of an integrated system that combines an organic electrochemical transistor (OECT) array for bladder fullness detection with an SMA spring actuator to facilitate voiding. To achieve this unique sensing-actuation design, first the SMAspring actuator strain sensor device was optimised for improved voiding efficiency, power consumption, stress on the bladder, and thermal safety. Then, the developed OECT array sensor replaced the strain sensor. The first part of this work focused on an SMA spring actuator strain sensor (Design 1), which included an encapsulation layer to minimise thermal effects. The voiding operation of the actuator consists of two phases: A bistable compression phase achieved by a SMA spring actuator, and a restoration phase initiated by two SMA wires. The SMA components were activated by a voltage signal application that resulted in high power consumption. Anewactuator with an integrated strain sensor was developed next that also included a bistable operation for the restoration phase with the help of a pre-shaped polyether ether ketone (PEEK) layer (Design 2). This approach reduced the power consumption by almost 10 times compared to previous SMA devices and reduced mechanical stress on the bladder from 0.75 N for the unshaped PEEK layer to 0.4 N. The fully bistable device showed a voiding efficiency of 95 − 100% in 10 seconds and restored the device within 30 seconds. The second part focused on the array development for detecting smooth muscle electrical activity through ion fluxes (e.g., potassium, sodium, and calcium). Individual OECTs with different dimensions were fabricated to optimise for sensitivity to low ionic concentrations. The OECT’s channel width of 300 µm and length of 50 µm enabled detection of potassium and sodium concentrations as low as 10 µM and calcium concentrations of 1 mM. These dimensions were then incorporated into a circular array with eight OECTs. The array’s capability in detecting sine wave signals with amplitudes as small as 5 mV, highlights its potential for responding to small biopotential signals produced by the bladder muscle.iv Finally, the OECT array sensor was integrated with the bistable actuator in Design 2. Aportable data acquisition system was developed to collect the output signals of eight OECTs concurrently. Artificial electromyography signals with amplitudes as small as 10 mV were applied to the array to demonstrate the sensor’s response to small signals while ensuring the actuator’s high voiding efficiency is maintained. This work provides a foundation for future in vivo testing, paving the way for clinically viable bladder assistive technologies that integrate real-time sensing with effective voiding.
Development of a Bistable Actuation and Organic Electrochemical Transistor-based Sensing System for Underactive Bladder Management
Holmes-Martin, K. M. (Author). 30 Sept 2025
Student thesis: Doctoral Thesis › Doctor of Philosophy (PhD)